Aerex® CTGB Cartridge Filter 30 in. 0.2 µm Code 7

SKU: CTGB73TP3 Categories: ,

Description

Description
Catalogue Number CTGB73TP3
Trade Name
  • Aerex®
Description Aerex CTGB Cartridge Filter 30 in. 0.2 µm Code 7

Product Information
Device Configuration Cartridge
Maximum Differential Pressure, bar (psid) Forward: 6.9 bar (100 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 145 °C. Reverse: 5.2 bar (75 psid) @ 25 °C, intermittent
Maximum Inlet Pressure, bar (psi) Forward – 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 145 °C; Reverse – 5.2 bar (75 psi) @ 25 °C
Cartridge Code Code 7
Good Manufacturing Practices These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Biological Information
Bacterial Endotoxins Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Media Aerex®
Sterilization 200 (150 forward/50 reverse) SIP cycles of 30 min @ 145 °C; SIP up to 165 hours in forward direction @ 145 °C
Bacterial Grow-Through The membrane has been qualified to retain bacteria when challenged for 21 days with a minimum Brevundimonas diminuta aerosol concentration of 1 x 10⁷ CFU/cm².
Wettability Hydrophobic

Physicochemical Information
Pore Size 0.2 µm
Bubble Point at 23 °C ≥900 mbar (13 psig) nitrogen with 60/40 % IPA/water
Gravimetric Extractables The extractables level was equal to or less than 35 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
HydroCorr ≤0.40 mL/min per 10-inch cartridge with water @ 1380 mbar (20 psig)
Nitrogen Diffusion at 23 °C ≤45 mL/min @ 690 mbar (10 psig) in 60/40 % IPA/water
Non-Fiber Releasing This product was manufactured with a PTFE membrane which meets the criteria for a “non-fiber releasing” filter as defined in 21 CFR 210.3 (b) (6).
Virus Aerosol Retention This product has been qualified to retain a ΦX174 virus aerosol challenge of 10⁸ to 10¹⁰ PFU at an air flow rate of 50 SCFM per 10-inch cartridge after 50 steam-in-place cycles at 145 °C.
USP Bacterial Endotoxins A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Dimensions
Cartridge Nominal Length 30 in. (75 cm)
Diameter 6.9 cm (2.7 in.)
Filtration Area 1.95 m²
Device Size 30 in.

Materials Information
Chemistry
  • Polytetrafluoroethylene (PTFE)
Device Material
  • Polypropylene
Seal Material Silicone (SI)
Support Material Polypropylene

Packaging Information
Material Size 3
Material Package Double Easy-Open bag

You may also like…